1.Description:
It is a 2CH delay relay module.It has 32 common functions to meet more application needs.It can control solenoid valves,water pumps,motors,light strips and more.
2.Feature:
1).It can be adjusted at any time from 0.01 seconds to 999 minutes.
2).It has 32 common functions,which can be freely selected according to your needs.
3).It supports the power-off memory function,and the parameters before the power-off can be retained when the power is accidentally cut off.
4).These two signals can be triggered at the same time,but they are independent of each other and do not affect each other.
3.Parameter:
1).Product Name:2CH Delay Relay Module
2).Input Voltage:DC 5V/DC 7-30V/AC 220V
3).Output Current:5A
4).Time Range:0.01 seconds-999 minutes
5).Work Temperature:-25℃~85℃
6).Work Humidity:5%~95%RH
7).Size:87*47*22mm
4.Wiring Port Description:
1).+:Input positive
2).-:Input negative
3).IN+:Positive signal input terminal
4).IN-:Negative terminal of signal input terminal
5).NO:The relay is normally open interface,the relay is suspended before it is closed,and it is short-circuited with COM after it is closed.
6).COM:Relay Common Interface
7).NC:Relay normally closed interface,short-circuit with COM before the relay pulls in,and then hangs in the air after pull-in
5.Function Description:
1).P-11:Jog (input a signal,the relay turn on,the signal disappears,the relay turn off)
2).P-12:Self-locking (input a signal,the relay turn on,input a signal again,the relay turn off)
3).P-13:After inputting a signal,the relay will stop automatically when it is turn on for A second;the trigger is invalid during the delay period
4).P-14:After inputting a signal,the relay will stop automatically when it is turn on for A second;it will trigger a re-timing during the delay period.
5).P-15:Input a signal,the relay will stop automatically when it is turn on for A second;trigger the superposition timing during the delay period
6).P-16:Input a signal,the relay will stop automatically when it is turn on for A second;reset will be triggered during the delay period
7).P-17:Input a signal,the relay is turn on,the input signal is disconnected,and the timing starts.After A second,the power is turned off.During the delay period,the signal is input again to keep the output,and the timing stops.
8).P-18:After the power is turned on,the relay will turn on immediately,and the power will be turned off after a delay of A seconds;until the next power on
9).P-21:Input a signal,after a delay of A seconds,the relay will turn on
10).P-22:Input a signal once,after more than A seconds,the relay will turn on,the signal will disappear,and the relay will stop
11).P-23:After the signal disappears for more than A seconds,the relay is turn on,the signal disappears,and the relay stops
12).P-24:The signal has been input for more than A seconds,the relay is turn on,and after the signal disappears for more than A seconds,the relay stops
13).P-25:After the signal has been input for more than A seconds,the relay will turn on,and after the signal has been input again for more than A seconds,the relay will turn off.
14).P-26:Input signal all the time,the relay will stop after being turn on for A seconds,the signal disappears,and the relay will be turn on again and then stop after A second
15).P-27:If there is a pulse signal,the relay turn off;if there is no pulse signal,the relay delays A second to turn on;(the signal continues or the signal disappears,it is regarded as no pulse signal)
16).P-28:After the power is turned on,after a delay of A seconds,the relay will turn on until the power is turned off
17).P-31:After the power is turned on,the relay will be turn on for A seconds,disconnected for B seconds,infinite loop,power off and stop
18).P-32:Input the signal all the time,start the infinite loop of P-31;the signal disappears,terminate the loop
19).P-33:Input the signal once to start the infinite loop of P-31;input the signal again to terminate the loop
20).P-34:After the power is turned on,after a delay of A seconds,the relay will turn on and stop after turn on for B seconds
21).P-35:Input signal all the time,after a delay of A seconds,the relay will turn on,and stop after turn on B seconds
22).P-36:Input the signal all the time,after A second,the relay will turn on,and it will turn off after B seconds,the signal disappears,and the timer is cleared and stopped.
23).P-37:Input signal all the time,the relay will stop automatically when it is turn on for A seconds,and then time B seconds after it stops,the signal triggering is invalid within the A+B time.
24).P-38:Input signal all the time,the relay will stop automatically when it is turn on for A seconds.After it stops timing for B seconds,it will automatically stop when it is turn on again for A seconds.
25).P-41:The input signal does not act all the time,the signal disappears and triggers,and the relay is disconnected after a delay of A time.
26).P-42:The signal disappears,after the delay time A,the relay works,and the working time B ends
27).P-43:The signal disappears.After the time of A exceeds,the relay will work,and the time of work B will end.
28).P-44:After inputting a signal more than A times,the relay will turn on for B seconds and stop
29).P-45:After the power is turned on,the relay 1 works for A seconds and then disconnects;the relay 2 works for B seconds and then disconnects
30).P-46:Input signal 1 once,after relay 1 works for A seconds and disconnects;relay 2 works for B seconds and disconnects
31).P-47:Input signal 1 once,after relay 1 works for A seconds;relay 2 starts to work;after B seconds,relays 1 and 2 are disconnected at the same time
32).P-48:After power-on,relay 1 works for A seconds and then disconnects;stops for B seconds;relay 2 works for C seconds and disconnects for D seconds;it keeps circulating
6.Application:
1).Control home appliances
2).Control industrial machinery
3).Automatic sprinkler irrigation
Paket : SOP
Anwendung : Relay Module
Art : Logik IC
Betriebstemperatur : -25~85 Celsuis
Versorgungsmaterial-Spannung : DC 5V/7-30V/AC 220V
ist individuell : Ja
Bedingung : Neu
Markenname : IST
Ursprung : CN (Herkunft)
Modellnummer : 2 Channel Delay Relay
Output Current : 5A
Time Range : 0.01 seconds-999 minutes
Feature 1 : 2 Channel Delay Relay
Feature 2 : Pulse Trigger Relay