2 kanal Verzögerung Relais Schalter Modul Puls Trigger Power-Off Zyklus Timer 0,01 S ~ 999M Einstellbare DC 5V 12V 24V AC 220V 5A

USD 10.90USD 16.77

2 kanal Verzögerung Relais Schalter Modul Puls Trigger Power-Off Zyklus Timer 0,01 S ~ 999M Einstellbare DC 5V 12V 24V AC 220V 5A

Description

2 Channel Delay Relay Switch Module Pulse Trigger Power-Off Cycle Timer 0.01S~999M Adjustable DC 5V 12V 24V AC 220V 5A

1.Description:

It is a 2CH delay relay module.It has 32 common functions to meet more application needs.It can control solenoid valves,water pumps,motors,light strips and more.

2.Feature:

1).It can be adjusted at any time from 0.01 seconds to 999 minutes.

2).It has 32 common functions,which can be freely selected according to your needs.

3).It supports the power-off memory function,and the parameters before the power-off can be retained when the power is accidentally cut off.

4).These two signals can be triggered at the same time,but they are independent of each other and do not affect each other.

3.Parameter:

1).Product Name:2CH Delay Relay Module

2).Input Voltage:DC 5V/DC 7-30V/AC 220V

3).Output Current:5A

4).Time Range:0.01 seconds-999 minutes

5).Work Temperature:-25℃~85℃

6).Work Humidity:5%~95%RH

7).Size:87*47*22mm

4.Wiring Port Description:

1).+:Input positive

2).-:Input negative

3).IN+:Positive signal input terminal

4).IN-:Negative terminal of signal input terminal

5).NO:The relay is normally open interface,the relay is suspended before it is closed,and it is short-circuited with COM after it is closed.

6).COM:Relay Common Interface

7).NC:Relay normally closed interface,short-circuit with COM before the relay pulls in,and then hangs in the air after pull-in

5.Function Description:

1).P-11:Jog (input a signal,the relay turn on,the signal disappears,the relay turn off)

2).P-12:Self-locking (input a signal,the relay turn on,input a signal again,the relay turn off)

3).P-13:After inputting a signal,the relay will stop automatically when it is turn on for A second;the trigger is invalid during the delay period

4).P-14:After inputting a signal,the relay will stop automatically when it is turn on for A second;it will trigger a re-timing during the delay period.

5).P-15:Input a signal,the relay will stop automatically when it is turn on for A second;trigger the superposition timing during the delay period

6).P-16:Input a signal,the relay will stop automatically when it is turn on for A second;reset will be triggered during the delay period

7).P-17:Input a signal,the relay is turn on,the input signal is disconnected,and the timing starts.After A second,the power is turned off.During the delay period,the signal is input again to keep the output,and the timing stops.

8).P-18:After the power is turned on,the relay will turn on immediately,and the power will be turned off after a delay of A seconds;until the next power on

9).P-21:Input a signal,after a delay of A seconds,the relay will turn on

10).P-22:Input a signal once,after more than A seconds,the relay will turn on,the signal will disappear,and the relay will stop

11).P-23:After the signal disappears for more than A seconds,the relay is turn on,the signal disappears,and the relay stops

12).P-24:The signal has been input for more than A seconds,the relay is turn on,and after the signal disappears for more than A seconds,the relay stops

13).P-25:After the signal has been input for more than A seconds,the relay will turn on,and after the signal has been input again for more than A seconds,the relay will turn off.

14).P-26:Input signal all the time,the relay will stop after being turn on for A seconds,the signal disappears,and the relay will be turn on again and then stop after A second

15).P-27:If there is a pulse signal,the relay turn off;if there is no pulse signal,the relay delays A second to turn on;(the signal continues or the signal disappears,it is regarded as no pulse signal)

16).P-28:After the power is turned on,after a delay of A seconds,the relay will turn on until the power is turned off

17).P-31:After the power is turned on,the relay will be turn on for A seconds,disconnected for B seconds,infinite loop,power off and stop

18).P-32:Input the signal all the time,start the infinite loop of P-31;the signal disappears,terminate the loop

19).P-33:Input the signal once to start the infinite loop of P-31;input the signal again to terminate the loop

20).P-34:After the power is turned on,after a delay of A seconds,the relay will turn on and stop after turn on for B seconds

21).P-35:Input signal all the time,after a delay of A seconds,the relay will turn on,and stop after turn on B seconds

22).P-36:Input the signal all the time,after A second,the relay will turn on,and it will turn off after B seconds,the signal disappears,and the timer is cleared and stopped.

23).P-37:Input signal all the time,the relay will stop automatically when it is turn on for A seconds,and then time B seconds after it stops,the signal triggering is invalid within the A+B time.

24).P-38:Input signal all the time,the relay will stop automatically when it is turn on for A seconds.After it stops timing for B seconds,it will automatically stop when it is turn on again for A seconds.

25).P-41:The input signal does not act all the time,the signal disappears and triggers,and the relay is disconnected after a delay of A time.

26).P-42:The signal disappears,after the delay time A,the relay works,and the working time B ends

27).P-43:The signal disappears.After the time of A exceeds,the relay will work,and the time of work B will end.

28).P-44:After inputting a signal more than A times,the relay will turn on for B seconds and stop

29).P-45:After the power is turned on,the relay 1 works for A seconds and then disconnects;the relay 2 works for B seconds and then disconnects

30).P-46:Input signal 1 once,after relay 1 works for A seconds and disconnects;relay 2 works for B seconds and disconnects

31).P-47:Input signal 1 once,after relay 1 works for A seconds;relay 2 starts to work;after B seconds,relays 1 and 2 are disconnected at the same time

32).P-48:After power-on,relay 1 works for A seconds and then disconnects;stops for B seconds;relay 2 works for C seconds and disconnects for D seconds;it keeps circulating

6.Application:

1).Control home appliances

2).Control industrial machinery

3).Automatic sprinkler irrigation

Specification

Paket : SOP

Anwendung : Relay Module

Art : Logik IC

Betriebstemperatur : -25~85 Celsuis

Versorgungsmaterial-Spannung : DC 5V/7-30V/AC 220V

ist individuell : Ja

Bedingung : Neu

Markenname : IST

Ursprung : CN (Herkunft)

Modellnummer : 2 Channel Delay Relay

Output Current : 5A

Time Range : 0.01 seconds-999 minutes

Feature 1 : 2 Channel Delay Relay

Feature 2 : Pulse Trigger Relay

IKCM15F60GA
USD 7.80
IKCM15F60GA
USD 8.30
Neue Timer H3CR-H8L M AC220V
USD 52.08USD 80.12
+